THE BUILDING PRODUCT E-BULLETIN

NEWSLETTER SIGNUP

05 January 2023

Campus Central – University of Stirling
FIEGER Ltd

Swatton Barn, Badbury, Swindon, SN4 0EU

T: 01793 676450
E: info@fieger.co.uk
W: https://www.fieger.co.uk/

Campus Central – University of Stirling

The Campus Central project is one of the University’s biggest infrastructure investments since its inception. The project involved the refurbishment of the existing Atrium as well as the construction of a new three-storey building at the heart of the campus, providing students and staff with a host of new study and social spaces.

Natural ventilation, using double-glazed louvres to complement the natural lighting effect, was seen as a sustainable approach to maintaining a comfortable environment.

The design, by Page Park architects, specified FIEGER FLW 32 glass louvre vents to provide both general ventilation and emergency smoke control. Working closely with the façade contractor, Marshall Brown Ltd, a total of 17 no. FIEGER FLW 32_17 SmoTec louvre windows were supplied, each comprising Guardian SunGuard SN 70/35 solar control double-glazing.

Client: University of Sterling

Architects: Page Park Architects

Main Contractor: Robertson Construction Ltd

Façade Contractor: Marshall Brown Ltd

To meet the architect’s specific requirements and to comply with The Scottish Building Regulations, the vents had a bespoke design comprising 200 mm high louvre blades up to 1100 mm, with stainless steel security bars, and larger louvre blades above.

The vents were supplied complete with Gröninger ML 1500 24V DC actuators, fitted to the side-frames. This motor was selected due to its safety feature of being programmable for anti-trapping, as well as the built-in auxiliary contacts, which meant it could be easily connected to the Building Management System.

To facilitate installation into the curtain walling, the vents were manufactured with integral 17 x 32 mm glazing adapters.

All of the units were finished in a Tiger Drylac anodized effect finish (068/60307 C33) to match the surrounding facade framework.

A key characteristic of the vents is the energy efficient design, achieved by the class-leading low air leakage rate, together with low U-values.

FIEGER units are tested across a wide range of standards, including EN 12101-2 for natural smoke vents and BS 6180: 2011 Barrier loading.

FIEGER Products

Application: Ventilation & Smoke Control

Type: FLW32 SmoTec

Colour: Tiger Drylac 068/60307 C33


Photo Credit: Paul Zanre